  • undefined

WTY Series Pressure Temperature Measuring Instrument

Optional models: WTY-203 on-site display and output 4-20mA signal WTY-204 on-site display and output thermocouple signal WTY-205 on-site display and output platinum resistance signal Pt100

Detailed introduction

1. Overview

 

WTY series pressure temperature measuring instruments have greater innovation and development than traditional pressure temperature measuring instruments. The volume of the temperature package can be reduced to 1/30 of the original. The sensor thermal resistor is creatively built into the temperature measuring element, realizing the temperature measurement function of mechatronics, forming a multifunctional series of temperature measuring instruments with remote transmission, shockproof, corrosion-resistant, electric contacts, temperature signal transmission, etc. with the pressure temperature instrument as the basic temperature measurement function, becoming a special instrument for motor bearing and cooler temperature measurement. This series is a non-explosion-proof pressure temperature measuring instrument.

The instrument has liquid pressure type, steam pressure type and gas pressure type temperature instruments.

Liquid pressure temperature instrument, the temperature package size can be minimized. The instrument has equal scale and non-equal scale options.

The instrument has intuitive readings, fast response speed, high sensitivity and long life. It combines the advantages of glass rod thermometer and bimetallic thermometer type thermometer. It is currently a mechanical temperature measuring instrument with a wide range of applications and comprehensive performance.

 

BWTY-205防爆仪表

WTY-205

2. Product Features

 

a. Convenient observation, clear reading, sensitive temperature measurement, stable performance, strong shock resistance;

b. Can display on site and output remote transmission signals;

c. Has integrated functions of sensing, display and remote transmission.

3. Model meaning

  

 

4. Working conditions

 

a. Ambient temperature -20~40℃;

b. Relative humidity not more than 95% (+25℃).

5. Technical performance

 

a. Temperature measurement range: 0~100℃;

b. Accuracy level: 2.0 or 1.5;

c. Probe size: 10mm in diameter, including thread length 50 (or as required by the user. The probe size of this type of instrument can be smaller);

d. Probe mounting thread: M16x1.5 (or as required by the user);

e. Output signal: Pt100 (or thermocouple, 4-20mA);

f. Measuring distance: 1.5M (or as required by the user);

g. Protection level: IP66;

h. Additional functions: anti-corrosion, insulation, please note when selecting.

6. Selection example

 Model: WTY-205. Technical conditions: Φ10x50mm, M16x1.5, measuring distance 1.5M.

7. Appearance and structural dimensions

Installation size: 82x82

  

 

8. Installation and wiring

 

a. When installing the instrument, check whether the explosion-proof mark on the instrument nameplate is consistent with the installation environment;

b. The connecting wire should be a copper shielded cable with a cross-sectional area of ​​not less than 0.2 square millimeters;

c. Open the instrument junction box, unscrew the compression nut of the cable entry device with a wrench, firmly connect the cable to the terminal (or terminal) in the junction box, then install the junction box and tighten the screws at the four corners;

d. The grounding screw on the instrument must be reliably grounded with a grounding wire;

e. During installation, the signal transmission line should be fixed with a tie head at a distance of no more than 300mm. When the signal transmission line is too long, it can be rolled up in a suitable position, never thrown around, and kept away from heating equipment;

f. After the instrument is used, it should be calibrated once a year. If conditions permit, you can calibrate it yourself or return it to the manufacturer for calibration;

g. When the sealing ring in the introduction device ages and deteriorates, it should be replaced in time;

h. The minimum outer diameter of the cable used by the user is Φ6, and it is recommended to use between Φ6-Φ12;

i. The size of the sealing ring is:

  

BWTY-205防爆仪表

 

j. Schematic diagram of the wiring row in the junction box

  

 

 Delivery time: This instrument is a customized product. Nanyang Huaye Explosion-proof Instrument Co., Ltd. promises to deliver the instrument within 7 working days after the order is placed. If you have a faster request, please contact us in time.

Key words:

WTY-203

WTY-204

WTY-205

Online Inquiry

If you have any questions, please feel free to contact us, we will sincerely answer for you!

Submit Message

* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.