Welcome to the official website of Nanyang Huaye Explosion-proof Instrument Co., Ltd!
Service Hotline:0377-61613169 | E-mail: abc@huayex.com
NZD Series Digital Temperature Meter
Optional models: NZD-0 single field display NZD-1 field display and output of platinum thermal resistance signal Pt100
Classification:
Detailed introduction
1. Overview
NZD digital temperature meter is a new on-site online measuring instrument. It uses self-powered display and does not require an external power supply. It uses imported ultra-low power consumption chips for acquisition and measurement and large digital LCD display. It has various forms and can be used in various fields. The product has novel design, compact structure, high precision and good stability. It is widely used in medicine, food, machinery, electricity and other industries. It is an ideal on-site test instrument.
2. Product appearance
3. Model Description
4. Technical indicators
a. Range: 0-100℃ or 0-200℃;
b. Accuracy: 0.5 grade;
c. Output signal: Pt100 or 4-20mA;
d. Installation thread: according to user needs;
e. Ambient temperature: -10~+50℃;
f. Ambient humidity: ≤95%;
g. Whole machine working current: <10 uA;
h. Power supply: 3.6V lithium battery
i. Protection level: IP66
5. Product Features
a. Small size, light weight, easy installation;
b. Ultra-low power consumption design;
c. Vibration resistance;
d. Long service life.
6. Dimensions


7. Product selection
When selecting a model, please specify the following technical conditions:
a. Measuring range;
b. Temperature package size;
c. Mounting thread;
d. Output signal: No signal transmission, other models available include Pt100 or 4-20mA;
e. Measuring distance;
8. Selection example
Model: NZD-0. Technical conditions: 0-100℃, Ø10×300, M27×2, hard tail
9. Installation precautions and wiring
a. During the installation or use of the instrument, the relevant provisions of the "Electrical Appliance Safety Regulations for Hazardous Locations of the People's Republic of China" shall be observed.
b. When installing and using the instrument, check whether the instrument nameplate logo is consistent with the installation environment.
c. The grounding screw on the instrument must be reliably grounded with a grounding wire.
d. During installation, the signal transmission line should be separated by a distance of no more than 300mm, fixed with a tie head, and never thrown randomly. It should be wired separately from the power line and away from heating equipment.
e. The instrument wiring 1, white, 2, red, 3, red, are the three terminals of Pt100 output respectively.
f. When the instrument is low on power, the display will be blurred. Please replace the battery in time.
Key words:
* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.