Welcome to the official website of Nanyang Huaye Explosion-proof Instrument Co., Ltd!
Service Hotline:0377-61613169 | E-mail: abc@huayex.com
Mine intrinsically safe integrated temperature and vibration transmitter
The intrinsically safe integrated temperature and vibration transmitter GWZD for mining can simultaneously measure the vibration and temperature at the installation location, and output two 4-20mA current signals corresponding to vibration and temperature respectively. It can be installed on the bearing seat or casing of the machine, and the output 4-20 mA current signal can be directly supplied to control systems such as PLC and DCS to monitor the operation of the machine in real time.
Classification:
Detailed introduction
1. Overview
The GWZD intrinsically safe integrated temperature and vibration transmitter for mining can simultaneously measure the vibration and temperature at the installation position, and output two 4-20mA current signals corresponding to vibration and temperature respectively.
It can be installed on the bearing seat or casing of the machine. The output 4-20 mA current signal can be directly supplied to control systems such as PLC and DCS to monitor the operation of the machine in real time.
The GWZD transmitter complies with the relevant requirements of GB/T 3836.1-2021 "Explosive Atmosphere Part 1: General Requirements for Equipment" and GB/T3836.4-2021 "Explosive Atmosphere Part 4: Equipment Protected by Intrinsically Safe "i"", and has the following characteristics: accurate signal, high precision, good long-term stability, maintenance-free, suitable for underground coal mines with methane explosive gas mixtures.
2. Model Description

3. Technical parameters
3.1 Environmental requirements
Ambient temperature -20~+40℃
Ambient humidity ≤98%(25℃)
3.2 Electrical parameters
Power supply voltage 24VDC ±10%, with reverse connection protection
Current output Two channels 4~20mA, load ≤500Ω
Electrical interface Integrated connecting wire, 4 *0.3mm2 mining shielded cable
3.3 Vibration measurement parameters
Vibration frequency response 3 ~ 1000Hz
Measurement accuracy ±6%FS
Measurement range 0 ~ 10/ 20/ 30/ 40/ 50 (mm/s), optional and customizable
3.4 Temperature measurement parameters
Measuring accuracy ±2%FS
Measuring range -20 ~ 100 (℃), customizable
Probe length 50mm, customizable
3.5 Mechanical parameters
Dimensions: Φ36 * 105 mm
Installation dimensions: M10 *1.5 *10 mm, customizable
Protection level: IP66
Shell material: 304 stainless steel
3.6 Explosion-proof related
Explosion-proof type Intrinsically safe
Explosion-proof mark ExibI Mb
Intrinsically safe parameters (temperature circuit) Ui= 28VDC, Ii= 93mA, Pi= 0.65W, Ci= 22nF, Li= 0
Intrinsically safe parameters (vibration circuit) Ui= 28VDC, Ii= 93mA, Pi= 0.65W, Ci= 22nF, Li= 0
4. Dimensions
5. Installation and wiring
5.1. Installation method
Install vertically or horizontally at the measured position, set the mounting screw hole at the measuring position, and tighten the transmitter for installation.
Pay attention to the hole depth to ensure that the temperature probe is in close contact with the measured surface.
The mounting thread is M10 *1.5, and the thread length is 10mm (customizable).
5.2. Wiring Instructions
In the GWZD transmitter, temperature and vibration measurements are both powered by a two-wire loop, with two outputs of 4-20mA current. See the wiring diagram for details.
Red wire: positive pole of power supply, black wire: 4-20mA vibration output,
Yellow wire: positive pole of power supply, green wire: 4-20mA temperature output

6. Notes
a. Check whether the explosion-proof mark on the shell is consistent with the site.
b. It is not allowed to open the shell with power on.
c. It is forbidden to open the cover within 1 minute after the power is off.
d. Components cannot be replaced without permission
Key words: